The maintenance of a PSA nitrogen generator is crucial for ensuring its long-term stable operation and high-efficiency production. Here are the maintenance methods for a PSA nitrogen generator:

Daily maintenance precautions

  1. Power supply, air supply and temperature conditions: Ensure that the power supply, air supply and temperature conditions required by the nitrogen generator are normally supplied, and the equipment can be normally turned on and off. Special attention should be paid to the stability of the power supply voltage to reduce damage to the controller and solenoid valve.
  2. Air storage tank pressure: Always pay attention to the pressure of the air storage tank and keep it between 0.6 and 0.8 MPa, not lower than the rated value.
  3. Automatic drain valve inspection: Check the automatic drain valve daily to prevent blockage. If it is blocked, it needs to be cleaned.
  4. Pressure gauge and nitrogen purity monitoring: Regularly check the pressure gauge on the nitrogen generator, record the pressure changes, and observe the flowmeter and nitrogen purity to maintain nitrogen purity.
  5. Cold dryer refrigeration effect check: Check the refrigeration effect of the cold dryer weekly to prevent water from entering the nitrogen generator due to cold dryer failure, which may cause poisoning of the carbon molecular sieve.
  6. Inspection of other components: Check the sensitivity of the solenoid valve and pneumatic valve, the pressure range of the pressure reducing valve, the accuracy of the gas analyzer, the tightness of the adsorption tower, the exhaust condition of the muffler, and the cleanliness of the inner tube of the flowmeter at irregular intervals.

Periodic maintenance

  1. Air treatment process inspection: Check the refrigeration effect of the cold dryer and replace the pipeline filter element regularly (once every six months) to ensure air quality.
  2. Activated carbon replacement: Replace the activated carbon in the nitrogen generator every 12 months to reduce the oil content in the air and avoid pollution of the carbon molecular sieve.
  3. Nitrogen analyzer detection and calibration: Detect and calibrate the nitrogen analyzer of the nitrogen generator. The service life of the P860 series nitrogen analyzer is about 2-3 years. It is recommended to replace it after expiration to avoid misjudgment of the nitrogen purity of the nitrogen generator.
  4. Inspection of solenoid valve and pneumatic valve: Check the solenoid valve and pneumatic valve. It is recommended that users have spare parts.
  5. Carbon molecular sieve replacement: Replace or add the carbon molecular sieve of the nitrogen generator every 5-6 years to ensure that the nitrogen production rate meets customer requirements.

The Importance of Maintenance and Care

  1. Extending Service Life: Regular maintenance can effectively prolong the service life of the nitrogen generator and reduce the occurrence of faults.

2.Improving Work Efficiency: Maintenance ensures the normal operation of the nitrogen generator and enhances the efficiency of nitrogen production.

3.Ensuring Nitrogen Purity: Timely replacement of carbon molecular sieves and other key components guarantees the purity of nitrogen.

In conclusion, the maintenance of a nitrogen generator is a systematic process that requires daily meticulous care and regular professional maintenance. Through these measures, the stable operation of the nitrogen generator can be ensured, production efficiency can be improved, and product quality can be guaranteed.